您好,欢迎来到仪器交易网!手机版|供应归档|本站服务|添加收藏|帮助中心
 当前位置: 首页 » 资料 » 其它资料

Human TGF-β ELISA Kit

Word文档
  • 文件类型:Word文档
  • 文件大?。?.2M
  • 更新日期:2015-08-20 08:37
  • 浏览次数:810   下载次数:2085
进入下载
详细介绍
 

                     

Human TGF-β ELISA Kit

For the quantitative in vitro determination of Human Transforming Growth factor β concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

ELISA

ENZYME linkED IMMUNOSORBENT ASSAY

INTENDED USE AND TEST PRINCIPLE

This TGF-β ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of TGF-β in the sample, this TGF-β ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus TGF-β concentration. The concentration of TGF-β in the samples is then determined by comparing the O.D. of the samples to the standard curve.

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximately 2000×g. Remove serum and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard(6 vial)

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20 Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by:480,240,120,60,30,15 pg/mL.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

PRECAUTIONS

1.         Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.

2.         Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.

3.         Do not use kit components beyond their expiration date.

4.         Use only deionized or distilled water to dilute reagents.

5.         Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

6.         Use fresh disposable pipette tips for each transfer to avoid contamination.

7.         Do not mix acid and sodium hypochlorite solutions.

8.         Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

9.         All samples should be disposed of in a manner that will inactivate viruses.

10.     Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.

11.     Substrate Solution is easily contaminated. If bluish prior to use, do not use.

12.     Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.

13.     Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

CALCULATION OF RESULTS

1.         This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.

2.         First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.

3.         To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4.         Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5.         Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.

6.         Assay range: 15 pg/mL – 480 pg/mL.

7.  Sensitivity: The minimum detectable dose of Human TGF-β is typically less than 1.0 pg/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human TGF-β. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)。

10.  Standard curve

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 
 
[ 资料搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

下载地址
 
  • 会员指数:
  • 企业认证:         
  • 联系人:陈云云(女士)    
  • 电话:021-54652189
  • 手机:15601655801
  • 地区:上海
推荐资料
本类下载排行
总下载排行
真人娱乐赌场 启东市| 台州市| 平舆县| 高唐县| 吉首市| 虎林市| 化德县| 自贡市| 荣成市| 汤原县| 朔州市| 庄浪县| 博乐市| 延川县| 泗阳县| 镇坪县| 射洪县| 永安市| 巴南区| 淅川县| 工布江达县| 南和县| 鹿泉市| 新乡市| 长乐市| 托克托县| 上犹县| 清涧县| 台湾省| 衡山县| 西充县| 洮南市| 西畴县| 凉城县| 光山县| 石门县| 翁牛特旗| 军事| 西城区| 湘乡市| 依兰县| 洞口县| 桦川县| 金秀| 沁水县| 抚宁县| 洱源县| 宜川县| 夏河县| 五峰| 大宁县| 贵德县| 汉源县| 汝阳县| 梧州市| 柘荣县| 塔河县| 泗阳县| 兴山县| 永顺县| 德格县| 尼玛县| 百色市| 吉安市| 闽清县| 喀喇沁旗| 虹口区| 精河县| 齐河县| 化德县| 陈巴尔虎旗| 石景山区| 壶关县| 鄂托克前旗| 永年县| 杭州市| 柳江县| 广州市| 兰州市| 八宿县| 黎平县| 吉首市| 科尔| 古丈县| 松阳县| 大悟县| 图片| 罗田县| 本溪| 永吉县| 宜川县| 益阳市| 吴川市| 伊川县| 柳林县| 滦平县| 奈曼旗| 西平县| 塔城市| 临朐县| 聂荣县| 新闻| 射阳县| 中牟县| 锦屏县| 康平县| 泌阳县| 应用必备| 印江| 庆元县| 筠连县| 搜索| 沈阳市| 津市市| 兰溪市| 霍邱县| 宜阳县| 泸州市| 汉川市| 海原县| 平利县| 南江县| 宜阳县| 德庆县| 怀安县| 贵港市| 金昌市| 申扎县| 衡东县| 静海县| 土默特左旗| 望谟县| 栾川县| 西乡县| 高雄县| 普兰店市| 阿拉善盟|